What is the function of Catch-All-Filter-Drier in HVAC system?

The Catch-All-Filer-Drier is a consumable brilliant gadget that can disposes of the considerable number of shortcomings of free filled reenactment by embellishment a mix into a spongy center. The center gives great filtration framework particularly to dampness, earth, acids and slop without the likelihood of desiccant powdering, pressing and getting away into the framework.
Catch-All Filer-Drier can kill
Moisture
Acid
Dirt
Sludge

Moisture Removing :

Moisture is an important factor in the whole HVAC systems, especially in refrigerant porous system. The presence of moisture, there is huge chance to easy formation of corrosion, acids and sludge etc.; using Catch-All-Filter-Drier helps to remove and protect to enter moisture into refrigerant system.

Acids Removing :

Some conditions like pressure, temperature help to forming chemical reaction. Consequently in refrigerant system acid-forming chemical reactions also can occur under certain conditions; for an example, when temperature increases in presence of moisture many refrigerants will react with oil to form acids.

Dirt Removing :

The type and nature of dirt may varies, but all dirt should be removed from refrigerant system. Especially some metallic contaminants or dirt like as cast iron dust, steel dust, corrosion dust, and copper or other metallic dust are really killer for HVAC system. They can damage compressor bearings, plug capillary tubes, expansion valves and important parts of the system.

Sludge and Varnish Removing :
All equipment are designed considering the decomposes of equipments of itself due to presence of moisture, dirt, acid and other particles. Although after taking this precaution to design and manufacture the system, no one can avoid completely to formation sludge and varnish inside the system because of breakdown of oil causes of discharge high temperature.

Catch-All-Filter-Drier is such a smart filter that can fight alone against the four major enemies and not allow passing them ahead.

Comments

Popular posts from this blog

Star Delta Starter Line Diagram and Its Working Principle

ELECTRICAL DISTRIBUTION BOARD DB WIRING

MCB: MINIATURE CIRCUIT BREAKER OPERATION BASIC

EARTH ELECTRODE RESISTANCE MEASUREMENT

SURGE ARRESTERS SPECIFICATION FOR 132 KV & 33 KV LINE

CURRENT TRANSFORMERS –CT USING

বৈচিত্রময় মরুভুমি

ELCTRICITY MYTH AND FACT

STEP AND TOUCH POTENTIAL: REDUCE ELECTRICAL HAZARD AND IMPROVE SAFETY AWARENESS

wazipoint

DMCA protected

The content is copyright protected to wazipoint and may not be reproduced on other websites.